Joist Hangers
Face-Mount Joist Hanger for 2x4 to 10x12 Joists
A face-mount joist hanger carries the end of a joist or beam where it meets a header, a ledger, or a wall. Its two mounting flanges turn outward and bolt to the face of the header, in plain view. Describe your joist and header below, and the hanger is made to fit them, level or pitched, with an optional ledge on the header's top. Also called an external flange joist hanger.
Made to order: ships in 10–12 business days.
- Ships free in the lower 48 states.
- 5% off orders over $2,000, 10% off over $5,000. No code needed.
01 Details
How a face-mount hanger goes in
Set the hanger against the header and fasten through its two mounting flanges. Lower the joist into the pocket, then fasten through the side flanges into the joist. Nothing is cut into the joist, and every fastener can be reached from the outside.
Face-mount or concealed
The two hangers differ in where the mounting flanges go. On this one they turn outward and show on both sides of the joist, which makes it the easier one to install. The concealed joist hanger turns them inward, behind the joist's end, where they can't be seen but the joist has to be grooved to clear the bolts.
How the configurator works
It walks you through five steps, and the 3D drawing follows every change:
- Bolt distances: NDS 12.5.1's minimum distances (recommended), its longer full design value distances, or no minimums.
- Your timbers: the joist's width and depth, the header's depth, how far the joist's top sits below the header's top, and the joist's pitch.
- The hanger: its height, the beam flanges along the joist, the mounting flanges on the header, the corners and the saddle, and a ledge if you want one.
- The bolts: the fastener, and where its rows go.
- Thickness and price: 3/16" or 1/4" steel.
Because it knows your timbers, it places the bolts for them: the joist's bolts back from its end, and every row clear of the joist's top and the header's top and bottom by the distances you chose. You can move the rows yourself. A design that breaks a rule is shown and held up until it's put right.
Sizes this hanger is made in
- Joist width: 1 1/2" to 10".
- Hanger height: 3 1/2" to 12", and no taller than the joist is deep.
- Mounting flanges, on the header: 1 1/2" to 3" wide each.
- Beam flanges, along the joist's sides: 2 1/2" to 5" wide.
- Pitch: level, or sloping down from the header as much as 45°.
- Fasteners: bolts and lag screws to 5/8".
- Corners: square, or clipped 1/2".
- Saddle, the seat under the joist: straight, or angled into the joist at the bottom.
- Steel: 3/16" or 1/4".
That spans joists and beams from 2x4 to 10x12. The pocket is 1/16" wider than the joist you enter, so the joist drops in. Leave room on the header for the flanges: a 4" joist with 2" mounting flanges makes a hanger about 8 1/2" wide. The configurator opens on that hanger, 7" tall, with 2 3/4" beam flanges and 1/2" bolts, on a rough-sawn 4x8 joist flush with the top of a 6x10 header.
A joist that slopes
For a rafter or a sloped joist, give the pitch as a rise in 12 or in degrees, from level to 45°. The mounting flanges stay plumb on the header's face. The seat and the beam flanges slope down with the joist, whose end is cut plumb to meet the header. The hanger's height is measured plumb, at the header, and the bolts keep their distances from the joist's sloping top and bottom.
A ledge on the header's top
A ledge is a plate across the top of the hanger that lies on the header's top. With one, the mounting flanges run up to the header's top, and the ledge reaches back onto it as far as you choose, up to the header's width. It can be plain, or have one or two rows of holes for fasteners down into the header. With clipped corners, the ledge's two back corners are clipped as well. No picture on this page shows one, so add it in the configurator to see it drawn.
When to add a ledge
- To set the hanger at the right height. The ledge sits on the header's top, so the hanger hangs there on its own while you drill and bolt it.
- When the joist is close to the header's top. A joist flush with the header, or nearly so, is where a ledge fits naturally.
- For fasteners from above. Holes in the ledge take fasteners down into the header's top, as well as through its face.
- For the look of a top-flange hanger.
Leave it off where the header's top has to stay clear, for decking, sheathing, or a plate on top of it. Whether your loads call for a ledge, or for its fasteners, is a question for your engineer.
Questions
Can I use lag screws or structural screws?
Lag screws, yes: choose one in the bolts step, and the holes are cut for it. Structural screws aren't covered by the NDS distances, so they can be chosen only with no minimum distances. The kind of fastener, its length, and how many your loads need are for your engineer or your building official to say.
Can the joist meet the header at a skew?
Not in the configurator, which makes hangers square to the header's face. For a skewed hanger, or a joist outside these sizes, send a sketch through the quote form and we'll draw it up for free.
What do the clipped corners and the angled saddle do?
Both are for looks. Clipped corners take 1/2" off the outer corners of the mounting flanges, and off the back corners of a ledge. The angled saddle runs 3/4" farther under the joist and tapers the bottom of the beam flanges to meet it.
The basics
- 3/16" or 1/4" A36 steel plate, your choice, laser cut and welded in our ISO 9001 shop in Texas.
- Holes are cut 1/16" larger than the fastener you choose. Fasteners aren't included.
- Enter your timber's real size, not its name. How to measure a timber.
- Bare steel, or matte black powder coat added in the cart.
- Ships free in the lower 48 states.
- No published load ratings. Ask your engineer, and see what to give them.
02 Compared
Made to your timbers, not to stock sizes
| This face-mount joist hanger | Stock joist hangers | |
|---|---|---|
| Sizes | Made to your timbers' real size | A few sizes for dressed lumber |
| Holes | Cut for the bolt you choose, 1/4" to 5/8" | Punched for one size |
| Steel | 3/16" plate (0.1875") | 18 to 14 gauge (0.048" to 0.075") |